BOZE CNC Ti | General Manufacturing

Cleaning & packaging (Class 8 cleanroom)

Cleaning & packaging (Class 8 cleanroom) capability for titanium components

Grade 1, Grade 2, Grade 5 (Ti-6Al-4V), Grade 7, Grade 9, Grade 23 Common Grades
Tank: Ø400 × 500 mm Thickness Range
No dimensional change Cutting Tolerance
No dimensional change Tolerance
Cleaned surface; no mechanical alteration Surface Finish

What is Cleaning & packaging (Class 8 cleanroom)?

Cleaning & packaging (Class 8 cleanroom) capability for titanium components

Integrated manufacturing capability for Cleaning & packaging (Class 8 cleanroom), supported by in-house QC, material certification, and engineering review.

Engineering Parameters & Capabilities

Ultrasonic cleaning uses high-frequency (25–130 kHz) sound waves to create cavitation bubbles in a cleaning solution. The implosion of these bubbles on the titanium surface dislodges contaminants (oil, chips, polishing compound) from blind holes, threads, and complex internal features, specifically for titanium components. Precision titanium components present unique challenges: Balancing dimensional accuracy with cost per part. Process selection (mill vs. turn vs. EDM vs. optimized for each feature.

Parameter Primary Method Alternative Method
Mechanism Cavitation implosion dislodges contaminants Pressure spray washing
Penetration Blind holes, threads, internal passages Line-of-sight only
Frequency 25 kHz (heavy) / 40 kHz (general) / 130 kHz (delicate) N/A

Engineering Capabilities & Limits

Integrated manufacturing capability for Cleaning & packaging (Class 8 cleanroom), supported by in-house QC, material certification, and engineering review.

Hole Types Supported

N/A

Heat Control Measures

Solution at 50–70°C for optimal cavitation. Sequential wash-rinse-dry with DI water final rinse.

Flatness & Stress Relief

No mechanical force applied — dimensional stability maintained.

Tolerance

No dimensional change

Secondary Operations & Downstream Processing

Enhance your component with our integrated downstream services:

HEPA Drying

HEPA-filtered hot air drying in Class 100 environment.

Cleanroom Packaging

Double-bagged in Class 10/100 with VCI lining.

Deburring

Deburring for cleaning & packaging (class 8 cleanroom) components.

Dimensional Inspection

Dimensional Inspection for cleaning & packaging (class 8 cleanroom) components.

Surface Treatment as Required

Surface Treatment as Required for cleaning & packaging (class 8 cleanroom) components.

Quality Assurance & Inspection

Inspection Items

  • Cleaning & packaging (Class 8 cleanroom) specific dimensional verification (CMM / vision)
  • Material grade verification (PMI / OES spectrometer)

Quality Standards & Certifications

  • ISO 9001:2015 — Quality Management System
  • AS9100D — Aerospace Quality Management
  • ASTM B265 — Titanium Strip, Sheet, and Plate Standard

Frequently Asked Questions

What titanium grades are suitable for Cleaning & packaging (Class 8 cleanroom)?
Cleaning & packaging (Class 8 cleanroom) can be performed on Grade 1, Grade 2, Grade 5 (Ti-6Al-4V), Grade 7, and other grades. The specific grade selection depends on the required mechanical properties, corrosion resistance, and end-use application requirements.
What tolerances can be achieved with Cleaning & packaging (Class 8 cleanroom)?
Typical achievable tolerances for Cleaning & packaging (Class 8 cleanroom) are No dimensional change. Tighter tolerances may be possible depending on part geometry, material condition, and quantity. Our engineering team reviews each project to determine the optimal tolerance-cost balance.
What quality certifications apply to Cleaning & packaging (Class 8 cleanroom)?
All Cleaning & packaging (Class 8 cleanroom) operations are performed under ISO 9001:2015 — Quality Management System, AS9100D — Aerospace Quality Management, ASTM B265 — Titanium Strip, Sheet, and Plate Standard certified quality management systems. Full traceability documentation, material certifications (EN 10204 3.1), and inspection reports are provided with each shipment.
What is the typical lead time for Cleaning & packaging (Class 8 cleanroom) projects?
Lead times for Cleaning & packaging (Class 8 cleanroom) vary by complexity and quantity. Prototype quantities (1-10 units) can typically be completed in 3-7 business days. Production quantities require 15-25 business days. Rush orders are available for qualifying projects. Contact our sales team for a specific timeline.
Can you provide DFM feedback for my Cleaning & packaging (Class 8 cleanroom) design?
Yes. We provide free Design for Manufacturability (DFM) analysis for all new projects. Simply upload your CAD file (STEP, DXF, or DWG format) and our engineering team will review your design and provide optimization suggestions within 24 hours.
About Boze Titanium Manufacturing Center

One Metal. One Focus. Infinite Precision.

Founded in 2011 in Baoji's Titanium Valley, BOZE Metal is dedicated exclusively to titanium — from raw material to precision engineering. AS9100D, ISO 13485 & ISO 9001 certified with 500+ clients across Aerospace, Medical & Motorsport industries, we deliver end-to-end precision titanium CNC machining with full material traceability from source to component.

Boze CNC Ti is the dedicated titanium manufacturing center of Baoji Boze Metal Products Co., Ltd.

AS9100D ISO 13485 ISO 9001 500+ Clients 15+ Years OEM/ODM