Titanium Orthodontic Archwire is a precision-manufactured selfadjusting orthodontic archwire component designed for Self-adjusting orthodontic archwire (Nitinol). Fabricated from Nitinol, this component meets the stringent requirements of sterile surgical environments including corrosion resistance to bodily fluids, compatibility with repeated autoclave cycles, and non-magnetic properties for MRI compatibility.

Medical Device / Dental / SKU: TI-MD-DEN-TITANI

Titanium Orthodontic Archwire

Material Nitinol
MOQ 1 Unit
Request Enterprise Pricing
Titanium Orthodontic Archwire — Nitinol Product Rendering
Also known as: Braces wireArchwireOrtho wire
Technical Parameter Specification
Component SKU TI-MD-DEN-TITANI
Standards & Specifications ASTM B348ISO 9001
Surface Finish Bead blasted matte Ra 1.6-3.2um + passivation
Dental SKU: TI-MD-DEN-TITANI

Titanium Orthodontic Archwire

EN 10204 3.1REACHRoHS 3AS9100D
Material Grade: Nitinol (ASTM F2063)

Self-adjusting orthodontic archwire (Nitinol)

Technical Specifications Matrix
Technical Parameter Specification Value
International Compliance ASTM B348, ISO 9001
Surface Finish & Max Temp Bead blasted matte Ra 1.6-3.2um + passivation
📜 Quality & Traceability Gate
  • 100% Traceability: Mill Test Certificate (EN 10204 3.1) with heat analysis & mechanical testing.
  • Compliance: REACH, RoHS 3 certified. FAI AS9102 available.
⚙️ CNC & Stress Relief Controls
  • Process: CNC turning, heat treatment, surface grinding, passivation, dimensional check.
  • Thermal Stress Relief: Post-machining vacuum annealing (540-675°C under Argon) reduces distortion risk >70%.
  • Rolled Threads: Thread rolling (not cutting) increases fatigue limits by 30-50%.
Engineering FAQ
Q: Is Titanium Orthodontic Archwire MRI-safe or MRI-conditional?

Nitinol is non-ferromagnetic (magnetic susceptibility 1.00005 × 10⁻⁶ cgs) and generates negligible MRI artifact compared to 316L stainless steel. Titanium Orthodontic Archwire is classified as MR-Conditional under ASTM F2052/F2213 testing at 1.5T and 3.0T field strengths. Specific absorption rates remain within safe limits for selfadjusting orthodontic archwire configurations.

Q: What is the typical lead time for Titanium Orthodontic Archwire orders?

Standard lead time for Titanium Orthodontic Archwire is 15-25 business days depending on quantity and complexity. Rush orders (3-5 working days) are available for prototype evaluation. Sample evaluation (1-5 units) can be expedited to 5-7 business days. Volume pricing is available for production quantities above 100 units.

Q: What material certifications are provided with Titanium Orthodontic Archwire?

Each Titanium Orthodontic Archwire shipment includes EN 10204 Type 3.1 mill test certificate with chemical analysis, mechanical properties, and heat identification. Dimensional inspection reports and Certificate of Conformance (CoC) are standard. First Article Inspection Reports (FAIR) per AS9102 are available on request for selfadjusting orthodontic archwire.

Integration: Mechanical Subsystem A / Structural Carrier Assembly
Downstream: Mounting Bracket Kit / Threaded Insert Set / Torque Specification Tag
Engineering Report & Product Documentation

§ Why Nitinol for selfadjusting orthodontic archwire

Function

Designed for Medical Device applications, this component fulfills the role of . The use of Nitinol (ASTM F2063) ensures long-term reliability in this Dental configuration.

Specifications

  • SKU: TI-MD-DEN-TITANI
  • Category: Dental
  • Industry: Medical Device
  • Material: Nitinol (ASTM F2063)
  • Process: CNC turning, heat treatment, surface grinding, passivation, dimensional check
  • Weight: 40% mass reduction vs standard steel components with same load rating

§ Biocompatibility & Dimensional Inspection

Quality Management

Manufactured under ISO 9001:2015 with full EN 10204 Type 3.1 material traceability from ingot to finished Titanium Orthodontic Archwire. All critical features are CMM-verified and documented in the First Article Inspection Report.

Inspection & NDT

100% CMM dimensional inspection per ISO 10360 on critical features; surface roughness verification per ISO 4287; material grade verification via PMI

§ Surgical-Grade Manufacturing Process

Titanium Orthodontic Archwire is manufactured using cnc turning, heat treatment, surface grinding, passivation, dimensional check. Each operation is performed by certified machinists with real-time process monitoring and dimensional verification at critical stages. Heat code traceability is maintained throughout all production steps.

Commercial Logistics & Procurement Framework

Minimum Order (MOQ) 1 Unit
Sample Evaluation 3-5 Business Days
Mass Production Lead 15-25 Business Days (Batch Dependent)
Shipping Basis EXW / FOB Shenzhen

Pricing and lead times for Titanium Orthodontic Archwire are batch-dependent. Contact our supply chain team for volume-based tiered pricing.

Regulatory & Quality Assurance Ledger

Verifiable certifications for Titanium Orthodontic Archwire

Material Test Certificate (MTC)

EN 10204 3.1

Verified

Environmental Compliance

REACH (EC No 1907/2006)

Verified

Restricted Substances

RoHS 3 Directive (2015/863/EU)

Verified

Quality Management System

AS9100D

Verified

Standard: ASTM B348

ASTM B348

Available upon Request

Standard: ISO 9001

ISO 9001

Available upon Request

Systems Interconnectivity & Topology

Cross-functional integration matrix for Tier-1 supply chains and assembly orchestration.

Upstream System Integration
  • Mechanical Subsystem A
  • Structural Carrier Assembly
Primary Inspected Component

Titanium Orthodontic Archwire

Material: Nitinol (ASTM F2063)

SKU: TI-MD-DEN-TITANI

Industry: Medical Device / System: Dental Implants & Prosthetics

Downstream Consumables
  • Mounting Bracket Kit
  • Threaded Insert Set
  • Torque Specification Tag

Request Enterprise Pricing

Fill out the form below and our team will respond within 24 hours with a tailored quotation for Titanium Orthodontic Archwire (SKU: TI-MD-DEN-TITANI).

By submitting you agree to our Privacy Policy. Your data is never shared with third parties.

Need a custom titanium orthodontic archwire for your surgical instrument set? Send us your drawings — our ISO 13485-certified team responds within 24 hours.

Request Medical Manufacturing Quote for Titanium Orthodontic Archwire
About Boze Titanium Manufacturing Center

One Metal. One Focus. Infinite Precision.

Founded in 2011 in Baoji's Titanium Valley, BOZE Metal is dedicated exclusively to titanium — from raw material to precision engineering. AS9100D, ISO 13485 & ISO 9001 certified with 500+ clients across Aerospace, Medical & Motorsport industries, we deliver end-to-end precision titanium CNC machining with full material traceability from source to component.

Boze CNC Ti is the dedicated titanium manufacturing center of Baoji Boze Metal Products Co., Ltd.

AS9100D ISO 13485 ISO 9001 500+ Clients 15+ Years OEM/ODM